GRT High-Temperature Connectors, up to +500 °C
−55 to +500 °C · stainless steel · hermetic receptacles

Chromel / alumel contacts · 4 to 47 contacts · −60 to +200 °C
PPH25M connectors carry thermocouple signals without adding measurement error: contacts are made of thermocouple alloys — chromel (X), alumel (A) and nickel-copper (K) — so the junction through the connector stays matched to the thermocouple wire. PPH25M is rated from −60 to +200 °C; PPH25AM from −60 to +150 °C.
| Parameter | Value | Condition |
|---|---|---|
| AC voltage | 400 V | |
| Contact resistance | ≤ 50 mΩ | |
| Insulation resistance | ≥ 1000 MΩ |
| Parameter | Value | Condition |
|---|---|---|
| Operating temperature | −60 to +200 °C | PPH25M, ≥ 600 h |
| Operating temperature | −60 to +150 °C | PPH25AM, ≥ 1000 h |
| Vibration | 1–600 Hz, 10 g | |
| Shock | 12 g, repeated | |
| Durability | 200 mating cycles |
Values not listed above — for example vibration level, leak rate or other environmental tests — can be tested to your requirements, including third-party testing. Specifications are subject to change; contact us for the current datasheet.
All contacts Ø 2.5 mm. X = chromel, A = alumel, K = nickel-copper.
| Contacts | Contact materials | Thread |
|---|---|---|
| 4 | 2 X + 2 K, or 2 X + 2 A | M24 × 1.5 |
| 7 | 3 X + 4 K, or 3 X + 4 A | M33 × 1.5 |
| 20 | 10 X + 10 A | M52 × 1.5 |
| 26 | 4 X + 22 A | M52 × 1.5 |
| 47 | 23 X + 24 A, or 35 X + 12 A | M64 × 1.5 |
Other material combinations on request.
| Series code | Version | Notes |
|---|---|---|
| …-1 / -2 / -4 | Receptacle: no backshell / straight / 90° unshielded backshell | |
| …-5 / -7 / -9 | Plug: no backshell / straight / 90° unshielded backshell | |
| …-8 / -10 | Plug: straight / 90° shielded backshell | |
| …-11 / -12 | Plug: straight / 90° cable-clamp shielded backshell |
A copper contact in a thermocouple circuit creates extra junctions and measurement error. PPH25M contacts are made of the same alloys as the thermocouple wire, so the signal passes through unchanged.
Part number, drawing, pin-out or a short description of your application.
Our engineers match the configuration and reply with a drawing and quotation.
Samples are made to your order. Third-party testing to your specification is available on request.
You test the samples in your own equipment and approve them.
Production follows the approved sample configuration.
Send your part number, pin-out or drawing. An engineer will reply by email.
−55 to +500 °C · stainless steel · hermetic receptacles
Up to +400 °C · 2 to 47 contacts · shielded or unshielded