PRG High-Temperature Circular Connectors, up to +400 °C

Up to +400 °C · 2 to 47 contacts · shielded or unshielded

PRG is a threaded high-temperature circular connector for DC and AC circuits in hot equipment. Six standard layouts from 2 to 47 contacts are rated up to +400 °C, with straight or 90°, shielded or unshielded backshells. A higher-current version with Ø 2.5 mm (25 A) and Ø 3.5 mm (50 A) contacts is rated from −55 to +350 °C.

Temperature
−60 to +400 °C
Contacts
2 to 47
Current rating
7–10 A (25 / 50 A version)
Shell
Threaded, shells 20–60

Request a quoteRequest drawing

Key features

  • Rated up to +400 °C
  • Threaded coupling
  • Six standard layouts: 2, 4, 7, 16, 26 and 47 contacts
  • Straight or 90° backshells, shielded or unshielded
  • Higher-current version: Ø 2.5 mm (25 A) and Ø 3.5 mm (50 A) contacts, −55 to +350 °C

Specifications

Electrical
ParameterValueCondition
Working voltage350 V
Contact resistance1.0 mΩ
Insulation resistance≥ 1000 MΩNormal conditions
Dielectric withstanding voltage≥ 1500 VHigher-current version, room temperature
Mechanical and environmental
ParameterValueCondition
Operating temperature−60 to +400 °C
Operating temperature−55 to +350 °CHigher-current version
Vibration1–2000 Hz, 10 g
Shock300 g single; 150 g repeated
Durability250 mating cycles, ≥ 100 h at temperature500 cycles for the higher-current version

Values not listed above — for example vibration level, leak rate or other environmental tests — can be tested to your requirements, including third-party testing. Specifications are subject to change; contact us for the current datasheet.

Contact layouts

Shell–contacts–layoutContactsCurrent per contactTotal currentMating force
20-2-6210 A20 A4.0 kg
28-4-8410 A40 A3.5 kg
28-7-9710 A70 A14.5 kg
40-16-41610 A160 A36.0 kg
48-26-3269 A234 A55.0 kg
60-47-3477 A329 A100.0 kg

Contact sizes and current ratings

Contact sizeEngaging diameterContact resistanceCurrent ratingWire size
Ø 2.5 mm2.5 mm≤ 17 mΩ25 A—
Ø 3.5 mm3.5 mm≤ 5 mΩ50 A—

How to order

PRG [shell] [contact] [contacts] [A] [backshell]

Example: PRG20J2AQ — Shell 20, pin contacts, 2 contacts, receptacle, straight unshielded backshell

Code segmentOptions
Shell
  • 20 28 40 48 60 Shell size
Contact
  • J / K Pin / socket
Contacts
  • 2 4 7 16 26 47 Number of contacts
Type
  • A Receptacle
  • (none) Plug
Backshell
  • P / Q Straight shielded / unshielded
  • R / S 90° shielded / unshielded

Contact diameter in the higher-current table is stated for that version; send us your current requirement.

Contact counts and terminations

Standard contact counts

  • 2
  • 4
  • 7
  • 16
  • 26
  • 47

Terminations

  • Solder

Typical applications

  • Engines and gas turbines
  • Industrial furnaces and heat treatment
  • High-temperature test rigs
  • Power generation equipment

Frequently asked questions

What temperature can PRG handle?

The standard layouts are rated from −60 to +400 °C; the higher-current version with 25 A and 50 A contacts from −55 to +350 °C.

Selection guides

From sample to production

  1. Send your requirement

    Part number, drawing, pin-out or a short description of your application.

  2. Configuration and quote

    Our engineers match the configuration and reply with a drawing and quotation.

  3. Samples

    Samples are made to your order. Third-party testing to your specification is available on request.

  4. Your approval

    You test the samples in your own equipment and approve them.

  5. Series production

    Production follows the approved sample configuration.

Need a quote or a drawing?

Send your part number, pin-out or drawing. An engineer will reply by email.