NPT-Sealed High-Current Feedthrough Studs, 105 to 750 A

105–750 A · 5000 VAC · leak < 1 × 10⁻⁸ Pa·m³/s

These sealed studs carry high current through the wall of a vacuum chamber or pressure vessel. The brass body seals with a tapered NPT thread; a copper stud is molded into epoxy insulation. Every unit is pressure-tested, and the leak rate is below 1 × 10⁻⁸ Pa·m³/s at 0.1 MPa differential.

Current rating
105–750 A
Withstanding voltage
5000 VAC
Sealing
NPT thread
Leak rate
< 1 × 10⁻⁸ Pa·m³/s
Temperature
−40 to +130 °C

Request a quoteRequest drawingDownload datasheet (PDF)PDF, 163 KB

Key features

  • High current through vacuum and pressure walls: 105 to 750 A
  • NPT tapered-thread seal, NPT 1/2 to NPT 1
  • 5000 VAC withstanding voltage, ≥ 5000 MΩ insulation resistance
  • Leak rate < 1 × 10⁻⁸ Pa·m³/s; every unit tested at 0.8 MPa
  • Copper stud, epoxy insulation, brass body, nuts and washers
  • Custom designs on request

Specifications

Electrical
ParameterValueCondition
Current rating105–750 ABy model
Dielectric withstanding voltage5000 VAC
Insulation resistance≥ 5000 MΩ
Sealing and materials
ParameterValueCondition
Leak rate< 1 × 10⁻⁸ Pa·m³/s0.1 MPa pressure differential
Hydrostatic pressure≥ 8 MPa type test; 0.8 ± 0.05 MPa on every unit
Operating temperature−40 to +130 °C
BodyBrass
StudCopper
InsulationEpoxy molding compound

Parameters not listed above — for example vibration level, leak rate or other environmental tests — can be tested to your requirements, including third-party testing.

Models

ModelMax. currentBody threadStud thread
C/JXZ-NTA-1105 ANPT 1/21/4-20 UNC
C/JXZ-NTB-1-G01275 ANPT 3/4M10
JXZ-24B500 ANPT 3/41/2-20 UNF
JXZ-23B500 ANPT 11/2-13 UNC
C/JXZ-NTD-1750 ANPT 15/8-20 UNF

Typical applications

  • Semiconductor manufacturing equipment
  • Vacuum furnaces and heat treatment
  • Refrigeration and gas compressors
  • Power distribution in pressure vessels

Frequently asked questions

How is each feedthrough tested?

Every unit is pressure-tested at 0.8 ± 0.05 MPa; the type test covers ≥ 8 MPa. Leak rate is below 1 × 10⁻⁸ Pa·m³/s at 0.1 MPa differential.

Can you make other currents or threads?

Yes. Send us current, voltage, wall thread and length and we will design a feedthrough to suit.

Selection guides

From sample to production

  1. Send your requirements

    Part number, drawing, pin-out or a short description of your application.

  2. Configuration and quote

    Our engineers match the configuration and reply with a drawing and quotation.

  3. Samples

    Samples are built to order. The minimum order quantity is 10 pieces, and samples and production orders each take 4–8 weeks. Third-party testing to your specification is available on request.

  4. Your approval

    You test the samples in your own equipment and approve them.

  5. Series production

    Production follows the approved sample configuration, with machining, molding, plating and assembly in our own Shenyang factory.

Need a quote or a drawing?

Send your part number, pin-out or drawing. Every inquiry is acknowledged by email within 1 business day, and an engineer follows up with a matched configuration, drawing or quotation.

Request a quote