NPT-Sealed High-Current Feedthrough Studs, 105 to 750 A
105–750 A · 5000 VAC · leak < 1 × 10⁻⁸ Pa·m³/s

105–1000 A · stainless steel · O-ring seal
O-ring sealed studs mount through a threaded hole or panel and seal with a fluorosilicone, FKM or HNBR O-ring. The stainless-steel body carries a copper stud in epoxy insulation for currents up to 1000 A. Leak rate is below 1 × 10⁻⁸ Pa·m³/s at 0.1 MPa differential, and every unit is pressure-tested.
| Parameter | Value | Condition |
|---|---|---|
| Current rating | 105–1000 A | By model |
| Dielectric withstanding voltage | 5000 VAC | |
| Insulation resistance | ≥ 5000 MΩ |
| Parameter | Value | Condition |
|---|---|---|
| Leak rate | < 1 × 10⁻⁸ Pa·m³/s | 0.1 MPa pressure differential |
| Hydrostatic pressure | ≥ 8 MPa type test; 0.8 ± 0.05 MPa on every unit | |
| Operating temperature | −40 to +130 °C / −20 to +130 °C | Fluorosilicone / FKM O-ring |
| Body | Stainless steel | |
| Stud | Copper | |
| Insulation | Epoxy moulding compound |
Values not listed above — for example vibration level, leak rate or other environmental tests — can be tested to your requirements, including third-party testing. Specifications are subject to change; contact us for the current datasheet.
| Model | Max. current | Body thread | Stud thread |
|---|---|---|---|
| C/JXZ-TA-2 | 105 A | 3/4-16 UNF | 1/4-20 UNC |
| C/JXZ-TB-2 (FKM) | 275 A | 7/8-14 UNF | 3/8-16 UNC |
| C/JXZ-TC-2 | 500 A | 1-16 UN | 1/2-13 UNC |
| C/JXZ-TD-2 | 750 A | 1 1/4-16 UN | 5/8-11 UNC |
| JXZ-45A (HNBR) | 1000 A | 1 7/8-12 UN | 7/8-14 UNF |
Fluorosilicone for low temperatures (−40 °C); FKM for chemical and oil resistance (−20 °C); HNBR on the 1000 A model. Tell us your media and temperature.
Part number, drawing, pin-out or a short description of your application.
Our engineers match the configuration and reply with a drawing and quotation.
Samples are made to your order. Third-party testing to your specification is available on request.
You test the samples in your own equipment and approve them.
Production follows the approved sample configuration.
Send your part number, pin-out or drawing. An engineer will reply by email.
105–750 A · 5000 VAC · leak < 1 × 10⁻⁸ Pa·m³/s
Designed to your vessel · 450–750 A examples · to +170 °C