SHX33 Deep-Sea Rubber-Molded Underwater Connectors, 7000 m
7000 m rated · 3 to 16 contacts · Gigabit Ethernet version

7000 m rated · 2 to 10 contacts at 15 A · 1-contact 250 A power version
SHX34 is the large member of our rubber-molded underwater connector family, for subsea power. Multi-contact versions carry 10–15 A per contact, and the single-contact power version carries 250 A at 3000 V withstanding voltage. All versions are rated to 7000 m with 70 MPa pressure ratings mated and unmated.
| Parameter | Value | Condition |
|---|---|---|
| Rated operating depth | 7000 m | |
| Pressure rating, unmated (open face) | 70 MPa | |
| Pressure rating, mated | 70 MPa |
| Parameter | Value | Condition |
|---|---|---|
| Dielectric withstanding voltage | 3000 V | 2 to 6 contacts; 1-contact power version |
| Dielectric withstanding voltage | 2000 V | 8 to 10 contacts |
| Insulation resistance | ≥ 1000 MΩ | 500 VDC |
| Contact resistance | ≤ 10 mΩ | |
| Current rating | 15 A | 2 to 8 contacts |
| Current rating | 10 A | 10 contacts |
| Current rating | 250 A | 1-contact power version |
| Parameter | Value | Condition |
|---|---|---|
| Durability | 500 mating cycles | |
| Vibration | 10–500 Hz, 147 m/s² | Electrical interruption ≤ 1 μs |
| Shock | 100 g, half-sine, 11 ms | Electrical interruption ≤ 1 μs |
| Operating temperature | −40 to +60 °C | |
| Salt spray | 500 h |
Values not listed above — for example vibration level, leak rate or other environmental tests — can be tested to your requirements, including third-party testing. Specifications are subject to change; contact us for the current datasheet.
| Series code | Version | Notes |
|---|---|---|
| SHX34L | Cable plug | |
| SHX34H | Bulkhead receptacle | Stainless steel or brass |
| SHX34D | Dummy plug (protective cap) | |
| SHX34 (1-contact) | Power version, 250 A |
SHX34 [type] – [contacts] [pin/socket] [shell] [locking sleeve] [sleeve material] ([cable length])
Example: SHX34H–1KBM — Power version bulkhead receptacle, 1 socket contact, stainless-steel shell, male-thread locking sleeve
| Code segment | Options |
|---|---|
| Type | |
| Contacts | |
| Contact type | |
| Receptacle shell | |
| Locking sleeve | |
| Sleeve material | |
| Cable length |
Power version: plug with pin contact (SHX34L–1J…), receptacle with socket contact (SHX34H–1K…).
15 A per contact for 2 to 8 contacts, 10 A for 10 contacts, and 250 A for the single-contact power version.
Wet-mateable means the connector can be mated and unmated with water on the contact faces, for example on deck or at the surface. If you need to mate or unmate at depth, tell us the depth and conditions and we will review it for your project.
Part number, drawing, pin-out or a short description of your application.
Our engineers match the configuration and reply with a drawing and quotation.
Samples are made to your order. Third-party testing to your specification is available on request.
You test the samples in your own equipment and approve them.
Production follows the approved sample configuration.
Send your part number, pin-out or drawing. An engineer will reply by email.
7000 m rated · 3 to 16 contacts · Gigabit Ethernet version
7000 m rated · 2 to 8 contacts · compact size